AW-400 Aluminum Awning Windows — Ventilation Without Compromise
Top-hinged aluminum awning windows for controlled ventilation — suited to commercial facades and high-rise applications. Every value below is engineered and documented — send your openings and performance targets, and our engineers confirm feasibility before quoting.

AW-400 Engineering Parameters
Configuration ranges depend on glass build and panel size. Triple-glazed and laminated upgrades are available on request.
| Parameter | Value | Unit | Test Standard |
|---|---|---|---|
| U-Value | 2.0 – 2.6 | W/m²K | NFRC 100 |
| SHGC | 0.40 – 0.60 | — | NFRC 200 |
| Design Pressure (DP) | +45 / -55 | ±psf | ASTM E330 |
| Water Tightness | 400 – 500 | Pa | ASTM E331 |
| Air Infiltration | ≤ 0.15 | cfm/ft² | ASTM E283 |
| Acoustic (STC) | 30 – 35 | dB | ASTM E90 |
| Opening Angle | ≤ 30° | deg | — |
| Frame Depth | 65 | mm | — |
System Specification
- Glass tested: 5mm tempered + 12A argon + 5mm Low-E tempered
Customization & Delivery
Sizes to your rough openings, RAL powder coat or anodized finishes, glass builds per climate zone, and hardware programs to match your market. Part of the full aluminum windows line — inspected under the same pre-shipment process as every Lansen order, with a line-item quote within 24 hours.
Get a AW-400 Parameter Quote →
Related Reading
- Casement vs Awning Windows: Spec & Performance
- Drafty Aluminum Windows: Causes, Fixes & Specs
- Aluminum Window Types: 5 Operating Styles Compared
AW-400 is rated Uw 2.0 – 2.6 W/m²K (0.35 – 0.46 Btu/h·ft²°F). See whole-window performance data for all 10 Lansen systems — U-value, SHGC, DP rating, water and air figures, with the test standard behind each one.