A non-opening thermally broken aluminum skylight that brings controlled daylight into interiors while meeting overhead safety-glazing requirements. Laminated glass, Low-E coating, and argon fill manage heat and glare; the slim frame keeps the sightline clean. Every value below is a design target — send your opening size, roof pitch, and site loads and our engineers confirm feasibility before quoting.

SL-100 fixed skylight — Lansen factory, Foshan

SL-100 Engineering Parameters

Configuration ranges depend on glass build, unit size, and curb detail.

Parameter Value Unit Test Standard
U-Value (whole unit) 1.1 – 1.8 W/m²K NFRC 100 / EN 673
SHGC 0.30 – 0.60 — NFRC 200
Visible Transmittance 0.40 – 0.70 — NFRC 200
Design Pressure (DP) +65 / −75, site-specific psf ASTM E330
Water Tightness 300 – 600 Pa ASTM E331
Air Infiltration ≤ 0.10 cfm/ft² ASTM E283
Glazing Laminated double, Low-E + argon — Overhead safety glass
Operation Fixed (non-opening) — —
Frame Depth 65 / 75 / 85 mm —
Thermal Break 24mm PA66 GF25 mm —
Warranty Confirmed with quote — —

System Specification

The SL-100 uses a thermally broken aluminum frame with laminated safety glass on the interior ply — the overhead-glazing requirement that keeps glass in place if broken. Low-E coating and argon fill reduce solar heat gain and condensation; a stepped curb and integrated drainage shed water. Fixed units suit corridors, stairwells, and rooms where daylight is wanted without ventilation. Custom shapes (square, rectangular, round, pyramid) are available.

Customization & Delivery

Custom opening size, roof pitch, curb height, and glass spec. Finishes: powder coat, anodized, or woodgrain in custom RAL. Glass options: Low-E, argon, laminated, tempered, tinted, frit. MOQ, sample lead time, and production lead time are confirmed with your quotation; export packaging for container shipment.

SL-100 FAQ

Do overhead skylights need laminated glass?

Yes. The interior ply is laminated safety glass so fragments stay in place if the glass is ever broken — the standard requirement for overhead glazing.

Can a fixed skylight still be energy-efficient?

Yes. Low-E coating and argon fill keep the whole-unit U-value low, and the frame uses a 24mm PA66 GF25 thermal break to limit heat transfer.

What shapes and sizes are available?

Square, rectangular, round, and pyramid units, custom-built to your opening size and roof pitch.

How do I get exact performance numbers for my project?

Send your opening size, roof pitch, and site snow/wind loads. Our engineers confirm the specification and return a line-item quote.

Related Skylight Systems

Request a Line-Item Quote →

Related Reading