Every figure on this page is a whole-window value, published by system — because performance belongs to a specific frame and glass combination, not to a brand or a product family. Read the source column beside the table: thermal and solar values come from NFRC-accredited simulation. Structural, water, air and acoustic figures are design targets against the named ASTM method, and physical testing to that method can be arranged per project.

What this page is — and what it is not

This page publishes performance data together with the standard that governs it, not a certificate we hold for every variant. Two different kinds of number appear on it, and the distinction matters to anyone writing a specification.

NFRC simulation values. U-factor, SHGC and visible transmittance are derived through NFRC-accredited simulation for the profile and glass build-up described. A simulation report for the exact configuration is available with your quote, and it names the frame series, glazing make-up and spacer that were modelled.

Design targets. Design pressure, water tightness, air leakage and acoustic figures are the levels the system is engineered to reach, expressed against the ASTM method that would verify them. A passed physical test report to ASTM E330, E331, E283 or E90 is not held for every system. Where a project requires one, physical testing can be arranged through a third-party laboratory, or the figures can be confirmed against your own testing programme.

What we will not do is present a design target as a passed test. If you need a certified result, ask for it and we will tell you whether it exists for that configuration — before you commit.

Why we separate whole-window from centre-of-glass

A common shortcut in this industry is to quote the centre-of-glass U-value and let the reader assume it describes the window. It does not. The glass at the centre of a pane performs better than the glass at the edge, and both perform better than the frame. On a thermally broken aluminium window the difference between the centre-of-glass figure and the true whole-window Uw is typically 0.05 to 0.15 Btu/h·ft²·°F.

That gap is large enough to decide whether a project meets its energy target. Every value in the table below is a whole-window figure. Where a centre-of-glass value is also available for a configuration, we state it separately and label it as such.

Whole-window performance by system

U-values are given in both SI (W/m²K) and imperial (Btu/h·ft²·°F) units, because North American specifications are written in imperial while the underlying test data is usually generated in SI.

Whole-window performance — Lansen window and door systems. Uw and SHGC are NFRC-accredited simulation values; design pressure, water, air and acoustic are design targets against the named ASTM method. Read the source note below the table before quoting any figure.
System Type Uw
(W/m²K)
Uw
(Btu/h·ft²·°F)
SHGC Design Pressure
(±psf)
Water
(Pa)
Air
(cfm/ft²)
Acoustic Test standard
TT-300 Tilt & turn window 1.2 – 1.4 0.21 – 0.25 0.30 – 0.45 +55 / -65 600 ≤ 0.50 m³/h·m² 36 – 42 dB (Rw) EN 14351-1
FX-500 Fixed window 1.4 – 2.0 0.25 – 0.35 0.35 – 0.60 +70 / -80 800+ ≤ 0.05 35 – 42 dB (STC) NFRC 100, ASTM E330/E331/E283/E90
ED-400 Entry door 1.6 – 2.0 0.28 – 0.35 0.25 – 0.45 +55 / -65 600 ≤ 0.10 32 – 38 dB (STC) NFRC 100, ASTM E330/E331/E283/E90
CW-100 Casement window 1.8 – 2.4 0.32 – 0.42 0.35 – 0.55 +65 / -75 600 – 750 ≤ 0.10 32 – 38 dB (STC) NFRC 100, EN 673, ASTM E330/E331/E283/E90
PV-500 Pivot door 1.8 – 2.4 0.32 – 0.42 0.40 – 0.60 +40 / -50 400 – 500 ≤ 0.15 30 – 36 dB (STC) NFRC 100, ASTM E330/E331/E283/E90
FD-200 French door 1.8 – 2.4 0.32 – 0.42 0.35 – 0.55 +50 / -60 500 – 600 ≤ 0.15 30 – 36 dB (STC) NFRC 100, ASTM E330/E331/E283/E90
SW-200 Sliding window 2.0 – 2.8 0.35 – 0.49 0.40 – 0.65 +50 / -60 ≥ 450 ≤ 0.20 28 – 34 dB (STC) NFRC 100, EN 673, ASTM E330/E331/E283/E90
SD-100 Sliding door 2.0 – 2.6 0.35 – 0.46 0.40 – 0.65 +50 / -60 ≥ 450 ≤ 0.20 28 – 34 dB (STC) NFRC 100, ASTM E330/E331/E283/E90
AW-400 Awning window 2.0 – 2.6 0.35 – 0.46 0.40 – 0.60 +45 / -55 400 – 500 ≤ 0.15 30 – 35 dB (STC) NFRC 100, ASTM E330/E331/E283/E90
BF-300 Bi-fold door 2.0 – 2.6 0.35 – 0.46 0.40 – 0.65 +40 / -50 350 – 450 ≤ 0.25 26 – 32 dB (STC) NFRC 100, ASTM E330/E331/E283/E90

Values are typical ranges for the stated system and depend on glass build-up, panel size and hardware configuration. Confirm the exact values for your configuration in the quote.

Where each column comes from

Uw (both units) and SHGC — NFRC-accredited simulation for the stated profile and glass build-up. A simulation report for the exact configuration is issued with the quote.

Design pressure, water, air and acoustic — design targets against ASTM E330, E331, E283 and E90 respectively. These are not passed test results for every system. Physical testing to those methods can be arranged through a third-party laboratory for a project; confirm the testing scope against your own specification before treating any figure as a verified result.

If a document you need does not exist for your configuration, we will say so rather than substitute a design value for a test value.

What each test standard covers

Standard What it measures
NFRC 100 U-factor — whole-window heat loss, the basis of US energy-code compliance
NFRC 200 SHGC and visible transmittance — solar heat gain and daylight
EN 673 / EN 410 European equivalents for U-value and solar/light transmittance of glazing
EN 14351-1 The European product standard for windows and external doors — the full performance declaration
ASTM E330 Structural performance under uniform wind load — where the DP rating comes from
ASTM E331 Water penetration under static pressure
ASTM E283 Air infiltration rate at a stated pressure (1.57 psf)
ASTM E90 Airborne sound transmission — the basis of the STC / Rw figure
EN 1026 / EN 1027 European air permeability and water tightness tests
EN ISO 717-1 European weighted sound reduction index (Rw)
EN 13126 Durability of hardware — the cycle count a unit is rated for

Documentation issued with every quote

  • Configuration-specific performance values — the figures for the exact frame series, glass build-up and hardware in your quote
  • Glass documentation — manufacturer, coating and production date, carried on the glass as shipped
  • Coating verification — film thickness readings per batch (anodised, powder coat or PVDF)
  • Alloy composition — spectrometry report, typically 6063-T5/T6 or 6061-T6
  • Signed dimension sheets and production-floor video — see our pre-shipment process
  • NFRC simulation report for the exact configuration — covering your frame series, glass build-up and size, not just the product family
  • Physical test reports where they exist — for any system where third-party ASTM E330 / E331 / E283 / E90 testing has been carried out, that report is supplied; where it has not, we say so rather than imply it
Need a document we have not listed? Send your project location and the code it must satisfy. Our engineers will tell you which documents exist for your configuration and which would need third-party testing — before you commit, not after. That includes arranging ASTM structural, water, air or acoustic testing where your specification requires a passed report.

Request performance data for your configuration →